Information:
HC-9885 electrolyte analyzer uses international advanced ion-selective electrode. The detection sensitivity of the machine for Potassium, Sodium, Chloride, Calcium electrolyte, stability, anti-interference ability reached the advanced level of similar foreign models. The Chinese operational information management system of the machine meets the needs of the medical unit. The instrument uses advanced microprocessor control system to achieve a fully automated test. Potassium, sodium, chlorine, pH, total calcium, ionic calcium and other projects can be detected simultaneously.
Test range:
Technical Specification:
HC-9885 electrolyte analyzer uses international advanced ion-selective electrode. The detection sensitivity of the machine for Potassium, Sodium, Chloride, Calcium electrolyte, stability, anti-interference ability reached the advanced level of similar foreign models. The Chinese operational information management system of the machine meets the needs of the medical unit. The instrument uses advanced microprocessor control system to achieve a fully automated test. Potassium, sodium, chlorine, pH, total calcium, ionic calcium and other projects can be detected simultaneously.
Test range:
Analyte | Units | Range | Resolution | |
K+ | mmol/L | 0.40 | 15.00 | 0.01 |
Na+ | mmol/L | 30.0 | 200.0 | 0.1 |
Cl- | mmol/L | 30.0 | 200.0 | 0.1 |
iCa2+ | mmol/L | 0.10 | 5.00 | 0.01 |
pH | 4.00 | 9.00 | 0.01 | |
TCa2+ | mmol/L | Calculate | 0.01 |
Technical Specification:
Sample Types: | Blood , Serum , Plasma or Diluted Urine | |||||||||||
Sample Size: | 60ul ~ 220ul serum , urine | |||||||||||
Analysis Time: | 25 ~ 45 seconds serum (including 1-point calibration) (HC9883 & HC9885) | |||||||||||
35 ~ 60 seconds serum (including 1-point calibration) (HC9884 & HC9886) | ||||||||||||
Throughput: | 80 ~ 110 samples per hour | |||||||||||
Power Source: | AC220V, 50Hz +/- 10V | |||||||||||
Power Consume: | < 60W | |||||||||||
Instrument Size: | 420mm(H) x 240mm(W) x 360mm(L) | |||||||||||
Package Size: | 630mm(L) x 305mm(H) x 460mm(W)(FORMER) 695mm(L) x 320mm(H) x 480mm(W)(NEW) | |||||||||||
Environmental Temperature Range: | 10 ~ 35℃ | |||||||||||
Measurement Technology: | Direct Potentiometry | |||||||||||
Reagent Include: | Calibrant A, Calibrant B , Electrode Cleanning Solution , QC Solution , Internal Filling Solution for Electrode etc. |